Conductor Cable

Introducing our high-performance Conductor Cable, the perfect solution for industries seeking exceptional electrical transmission and power distribution capabilities. As a renowned manufacturer, supplier, and exporter with over 30 years of experience, we offer a popular range of ACSR Rabbit Conductor Cable, ACSR Weasel Conductor Cable, ACSR Zebra Conductor Cable, ACSR Panther Conductor Cable, and ACSR Dog Conductor Cable to meet new and diverse requirements. Our Conductor Cable boasts five phenomenal features:: incomparable tensile strength for ultimate reliability, superior conductivity that ensures efficient power flow, anti-corrosive properties for extended lifespan, lightweight yet robust design for easier installation, and unmatched flexibility to adapt to various applications. These features set our product apart from traditional alternatives and offer unmatched performance in demanding environments. With a perfect supply ability across All India, our Conductor Cables are trusted for their quality and versatility, making them the first choice for critical infrastructure projects and applications demanding the best in class. Choose our Conductor Cable for a combination of new-edge technology and time-tested durability, ensuring your power transmission needs are met with precision and excellence.

ACSR Dog Conductor Cable

MOQ : 100 Kilograms

  • Application
  • Other, Overhead power transmission and distribution lines
  • Cable Type
  • ACSR Dog Conductor
  • Color
  • Silver/metallic
  • Conductor Material
  • Other, Aluminium (outer layers), Galvanized Steel (core)
  • Conductor Shape
  • Other, Stranded round
  • Conductor Type
  • Other, ACSR (Aluminium Conductor Steel Reinforced)
  • Core Material
  • Galvanized steel
  • Core Number
  • 1
  • Diameter
  • 14.62 mm (approximate overall diameter)
  • Dielectiric Strength
  • N/A (bare conductor)
  • Dimension (L*W*H)
  • Depends on the drum/packaging
  • Features
  • High tensile strength, corrosion resistant, lightweight, suitable for long span installations
  • Impedance
  • Varies with installation, typically 0.318 ohm/km at 20C
  • Install Type
  • Aerial/overhead
  • Insulation Material
  • Other, None (bare conductor)
  • Length
  • Customizable as per order, typically supplied in drum lengths up to 2000 meters
  • Material
  • Aluminium and galvanized steel
  • Number of Conductor
  • 1 (single core)
  • Operating Temperature
  • -10C to 80C
  • Product Type
  • Overhead power conductor
  • Rated Temperature
  • Up to 75C
  • Size
  • Dog (standard ACSR code for 100 mm2 nominal aluminium area)
  • Storage Temperature
  • 0C to 50C, dry conditions
  • Tensile Strength
  • Minimum 12700 N
  • Usage & Applications
  • Transmission and distribution of electrical power in open air
  • Voltage
  • Other, Suitable for up to 33 kV applications
  • Weight
  • Approx. 395 kg/km

ACSR Moose Conductor Cable

MOQ : 100 Kilograms

  • Application
  • Other, Overhead power transmission and distribution lines
  • Cable Type
  • Overhead Transmission Conductor
  • Color
  • Silver (metallic)
  • Conductor Material
  • Other, Aluminum (EC Grade) and Steel (Galvanized Steel Core)
  • Conductor Shape
  • Other, Round/Stranded
  • Conductor Type
  • Other, ACSR (Aluminum Conductor Steel Reinforced)
  • Core Material
  • Galvanized Steel
  • Core Number
  • 1 (Steel Core)
  • Diameter
  • Approx. 31.77 mm
  • Dielectiric Strength
  • Not applicable (bare cable)
  • Dimension (L*W*H)
  • Diameter specific, length as per drum specification
  • Features
  • High tensile strength, corrosion resistance, excellent conductivity, lightweight, reliable, long service life
  • Impedance
  • Depends on installation and length
  • Install Type
  • Overhead
  • Insulation
  • None (Bare Conductor)
  • Insulation Material
  • Other, None (Bare Conductor)
  • Jacket Color
  • Other, Not applicable (aluminum finish)
  • Jacket Material
  • Other, None (Bare Conductor)
  • Length
  • Standard Drum Lengths (500m, 1000m, or customized as per requirement)
  • Material
  • Aluminum and Galvanized Steel
  • Number of Conductor
  • Typically 1 per cable (multi-stranded construction)
  • Operating Temperature
  • Up to 75C
  • Product Type
  • ACSR Moose Conductor Cable
  • Rated Temperature
  • Continuous operation up to 75C
  • Size
  • Moose (overall diameter approx. 31.77 mm)
  • Storage Temperature
  • -20C to +60C
  • Tensile Strength
  • Minimum 150 kN
  • Usage & Applications
  • Electrical Power Transmission and Distribution
  • Voltage
  • Other, Up to 400 kV (depends on configuration and application)
  • Weight
  • Approx. 1449 kg/km

ACSR Panther Conductor Cable

MOQ : 100 Kilograms

  • Application
  • Other, Used in overhead power transmission and distribution lines.
  • Armored Material
  • Not applicable.
  • Cable Type
  • ACSR (Aluminum Conductor Steel Reinforced).
  • Color
  • Silver (natural metal finish).
  • Conductor Material
  • Other, Aluminium (Al) and Galvanized Steel (core).
  • Conductor Shape
  • Other, Round, stranded.
  • Conductor Type
  • Other, Stranded conductor with steel core.
  • Connector Color
  • Not applicable.
  • Core Material
  • Galvanized steel.
  • Core Number
  • One steel core.
  • Diameter
  • Approx. 21.0 mm (overall nominal diameter).
  • Dielectiric Strength
  • Not applicable to bare conductor.
  • Dimension (L*W*H)
  • Varies as per drum size, cable diameter approx. 21.0 mm.
  • Features
  • High tensile strength, excellent conductivity, corrosion resistance, lightweight, and low sag.
  • Impedance
  • Approx. 0.146 ohm/km at 20C (varies by standard).
  • Install Type
  • Outdoor, aerial.
  • Insulation
  • None (bare).
  • Insulation Material
  • Other, None (bare conductor).
  • Jacket Color
  • Other, Not applicable.
  • Jacket Material
  • Other, None (bare conductor).
  • Length
  • Standard drum length of 2,000 to 3,000 meters (customizable on request).
  • Locking Type
  • Not applicable.
  • Material
  • Aluminium and galvanized steel.
  • Number of Conductor
  • 1 (single core cable, multi-wire strands).
  • Operating Temperature
  • Up to 75C continuous, short-circuit up to 150C.
  • Product Type
  • ACSR Panther Conductor Cable.
  • Rated Temperature
  • Up to 75C constant operating temperature.
  • Shield Material
  • Not applicable.
  • Size
  • 30/7 (30 Aluminium strands / 7 Steel strands), nominal area 150 sq.mm.
  • Storage Temperature
  • -20C to +50C standard storage.
  • Tensile Strength
  • 42.78 kN (min breaking force, typical ASTM/IS standard).
  • Usage & Applications
  • Power transmission and distribution overhead lines.
  • Voltage
  • Other, Suitable up to 132 kV (kilovolts).
  • Weight
  • Approx. 546 kg/km (may vary as per standard).

ACSR Rabbit Conductor Cable

MOQ : 100 Kilograms

  • Application
  • Other, Overhead power transmission and distribution
  • Cable Type
  • ACSR Rabbit
  • Color
  • Silver/Grey Metallic
  • Conductor Material
  • Other, Aluminium Stranded, Steel Reinforced Core
  • Conductor Shape
  • Round
  • Conductor Type
  • Other, ACSR (Aluminium Conductor Steel Reinforced)
  • Core Material
  • Galvanized Steel
  • Core Number
  • 1 Steel Core
  • Diameter
  • 11.1 mm
  • Dielectiric Strength
  • Not applicable (bare conductor)
  • Dimension (L*W*H)
  • Diameter Length, Diameter typically 11.1 mm
  • Features
  • High tensile strength, corrosion resistant, good conductivity, lightweight, low sag
  • Impedance
  • Approximately 0.3092 ohm/km at 20C
  • Install Type
  • Aerial installation
  • Insulation
  • None (Bare Conductor)
  • Insulation Material
  • Other, Uninsulated (Bare Conductor)
  • Jacket Material
  • Other, Not applicable (bare conductor)
  • Length
  • Customizable, typically supplied in standard drum lengths (e.g., 2 km)
  • Material
  • Aluminium and Galvanized Steel
  • Number of Conductor
  • 7 strands (6 Aluminium + 1 Steel)
  • Operating Temperature
  • Up to 75C
  • Product Type
  • Overhead Transmission Conductor
  • Rated Temperature
  • Up to 75C
  • Size
  • 30.38 sq. mm (Nominal Area)
  • Storage Temperature
  • -20C to 60C
  • Tensile Strength
  • Around 9.82 kN
  • Usage & Applications
  • Transmission and distribution of electricity
  • Voltage
  • Other, Suitable up to 33 kV
  • Weight
  • Approximately 101 kg/km

ACSR Racoon Conductor Cable

MOQ : 100 Kilograms

  • Application
  • Other, Overhead power transmission and distribution
  • Cable Type
  • ACSR Racoon
  • Color
  • Silver/Grey (natural metal finish)
  • Conductor Material
  • Other, Aluminum (outer strands) and steel (core)
  • Conductor Shape
  • Other, Stranded
  • Conductor Type
  • Other, Composite (Aluminum Conductor Steel Reinforced)
  • Core Material
  • Galvanized steel
  • Core Number
  • One Steel Core
  • Diameter
  • 13.62 mm (nominal overall diameter)
  • Dielectiric Strength
  • Not applicable (bare conductor)
  • Dimension (L*W*H)
  • Depends on length and drum size
  • Features
  • High strength, excellent conductivity, lightweight, corrosion resistant, long service life
  • Impedance
  • Depends on installation and length
  • Install Type
  • Overhead, suspended
  • Insulation
  • None (bare conductor)
  • Insulation Material
  • Other, None (bare conductor)
  • Jacket Color
  • Other, None (bare conductor)
  • Jacket Material
  • Other, None (bare conductor)
  • Length
  • Standard lengths as per requirement (usually 1000 meters per drum)
  • Material
  • Aluminum and galvanized steel
  • Number of Conductor
  • Typically one core (multi-stranded aluminum with one steel core)
  • Operating Temperature
  • Up to 75C
  • Product Type
  • ACSR (Aluminum Conductor Steel Reinforced) Cable
  • Rated Temperature
  • Up to 75C continuous operation
  • Size
  • 6/4.09 mm (Aluminum) + 1/4.09 mm (Steel) as per IS:398
  • Storage Temperature
  • -20C to +60C
  • Tensile Strength
  • High, suitable for overhead installation
  • Usage & Applications
  • Overhead transmission and distribution lines
  • Voltage
  • Other, Suitable for medium and high voltage transmission lines
  • Weight
  • Approximately 444 kg/km

ACSR Weasel Conductor Cable

MOQ : 100 Kilograms

  • Application
  • Other, Overhead power distribution and transmission lines
  • Cable Type
  • ACSR (Aluminum Conductor Steel Reinforced)
  • Color
  • Silver (natural metal finish)
  • Conductor Material
  • Other, Aluminum (strands) and Steel (core)
  • Conductor Shape
  • Other, Round strands
  • Conductor Type
  • Other, ACSR (Aluminum Conductor Steel Reinforced)
  • Core Material
  • Galvanized Steel
  • Core Number
  • 1 (steel core)
  • Diameter
  • Approx. 9.0 mm
  • Dielectiric Strength
  • Not Applicable (bare conductor)
  • Dimension (L*W*H)
  • Varies as per coil length and packaging
  • Features
  • High tensile strength, corrosion resistance, lightweight, excellent conductivity
  • Impedance
  • Variable depending on installation
  • Install Type
  • Overhead
  • Insulation
  • None (bare)
  • Insulation Material
  • Other, None (Bare Conductor)
  • Length
  • Standard lengths or as per requirement (typically 500m, 1000m reels)
  • Material
  • Aluminum and Steel
  • Number of Conductor
  • 7 (6 aluminum + 1 steel core)
  • Operating Temperature
  • Up to 75C
  • Product Type
  • Overhead Bare Conductor Cable
  • Rated Temperature
  • 75C
  • Size
  • Weasel (30/7), Nominal Area: 32 mm2
  • Storage Temperature
  • -20C to +60C
  • Tensile Strength
  • 35.5 kN (approx.)
  • Usage & Applications
  • Power transmission and distribution, overhead lines
  • Voltage
  • Other, Up to 33 kV
  • Weight
  • 112 kg/km (approx.)

ACSR Zebra Conductor Cable

MOQ : 100 Kilograms

  • Application
  • Other, Overhead power transmission and distribution
  • Armored Material
  • Steel core
  • Cable Type
  • ACSR (Aluminum Conductor Steel Reinforced)
  • Color
  • Silver
  • Conductor Material
  • Other, Aluminum (outer), Steel (core)
  • Conductor Shape
  • Round
  • Conductor Type
  • Other, Stranded (ACSR - Aluminum Conductor Steel Reinforced)
  • Core Material
  • Galvanized steel
  • Core Number
  • 1 (steel core)
  • Diameter
  • 28.62 mm (nominal)
  • Dielectiric Strength
  • Not applicable (bare conductor)
  • Dimension (L*W*H)
  • Varies as per length and coil size
  • Features
  • High strength, good conductivity, corrosion resistance, suitable for long-span installations, lightweight
  • Impedance
  • Varies (typically ~0.128 /km at 20C)
  • Install Type
  • Overhead
  • Insulation Material
  • Other, None (bare conductor)
  • Jacket Color
  • Other, Silver (natural aluminum color)
  • Jacket Material
  • Other, None (bare aluminum and steel)
  • Length
  • Standard or as per requirement (usually in kilometers or coils)
  • Material
  • Aluminum & Galvanized Steel
  • Number of Conductor
  • 7 steel wires (core) + 54 aluminum wires (outer)
  • Operating Temperature
  • Up to 75C continuous, short term up to 150C
  • Product Type
  • ACSR Zebra Conductor Cable
  • Rated Temperature
  • Up to 75C (standard)
  • Size
  • 54/7 (54 aluminum wires, 7 steel wires)
  • Storage Temperature
  • -20C to 60C (recommended)
  • Tensile Strength
  • Approximately 32.37 kN
  • Usage & Applications
  • Transmission and distribution lines, power grid infrastructure
  • Voltage
  • Other, 33kV and above (used for high voltage overhead transmission lines)
  • Weight
  • 1214 kg/km (approximate)


Back to top